Connect wifi to the Wi-Fi stick to the interface on the inverter 2. If you are scanning the loggers then be sure to scan the bar code on the logger itself and not the one on the inverter's spec label, see examples of the logger bar codes below: Simple connectivity has your Solis solar system online in just a few steps delivering ongoing comprehensive data analysis and fault finding anytime, anywhere. Otherwise, the communication quality may be affected. The next screen should say "Configuration Complete" and you may tap "OK (3/3)" to finish up the commissioning, The system needs betweenten and fifteen minutesto sendit'sfirst report in, so please wait until the system begins to show data onSolisCloudbefore leaving the site, Did you find it helpful? Note that all scripts use Python 3. Victor is the author of this solution article. View the total data of your PV plant. Wi-Fi trensmitting power: 802.11b/g/n: +20dBm/+18dBm/15dBm (Max) Data collection intervals: 5 minutes (adjustable:1-20 minutes) Preferences setting: Web server/Serial AT instruction. Router signal strength is low 4. Step 2: Input the information about the plant as required. Let us know how can we improve this article! Copyright@2020 Ginlong Technologies All rights reserved. 1. Unscrew the protective cap over the green COM port on the bottom of the inverter's wire box. Screenshot of the Status page in the configuration interface. 1. If it is not pingable and the password is good, then verify the signal strength of the WIFI Router, 3. Well also assume you agree to the way we use cookies and are ok with it as described in our Privacy policy, unless you choose to disable them altogether through your browser. Once you've connected to the "AP" network, return to, and then look for the home network that you wish to connect the logger to. Michael is the author of this solution article. Please follow the instructions below: Step3: Use your mobile phone to send a text message to the SIM card in the stick. We recommend something with a larger screen. Firmware Version: 3.16.9. i have recently installed a solar inverter which has a data logger > having an issue connecting it to my wifi network but it works fine with . Hi all, The AutoSave Draft feature is now disabled across the site. :). Copyright@2019 Ginlong Technologies All rights reserved, Dec-17-2019, Go Solis Webinar: 2020 CA Solar Mandate Compliance with Solis Inverters, Feb-11-2020, Go Solis Webinar: New Solis 125K 1500V Inverters plus AlsoEnergy: Better ROI for 2-40 MW Systems, Mounting, Wiring, and Commissioning 4G Single Phase Inverter - Video, Solis and the Tigo TS4 Platform; Tested and Harmonized Commercial Inverter 690.12 Rapid Shutdown Solutions, Contacting Technical Support for Solis Partners, Contacting Technical Support for Your Region, Go Solis 2020 Webinar #7: Testing Solis Inverters Beyond Certifications with PV Evolution Labs, Go Solis Mini Exchange#1: An Introduction to Energy Storage System, Go Solis Webinar #1: 2020 California Solar Mandate with Solis Inverters (12/17/2019, U.S.), Go Solis Webinar #2: The New Solis 125K 1500V Inverters plus Also Energy (2/11/2020, U.S.), Go Solis Webinar #3: Solis Hybrid Energy Storage Inverter with LG Chem (2/11/2020, U.S.), Go Solis Webinar #4: Solis Commercial Inverters (4/21/2020, U.S.), Go Solis Webinar #5: Solis inverters and SunSpec Alliance (5/5/2020, U.S.), Go Solis Webinar #6: Solis and Tigo TS4 Platform - Tested and Harmonized Commercial Inverter 690.12 Rapid Shutdown Solutions, Go Solis Webinar #8 Solis Inverters and SunSpec Alliance: The Importance of SunSpec CSIP 2030.5, Ginlong Solis: Standard Lead Time from Ningbo to USA/Canada, How to Determine the Firmware Version of your Solis Inverter, Lowering Output Power of Single Phase Solis Inverter, MA Compatibility Between Single Phase 4G and 2G inverters, Solis 3PH and CSI GS Product Number and Description 20180331, Starting Serial Numbers and HMI VER- ISO-NE / Rule 21 P1 and P3, String Sizing for 1P and 3P Inverters. Intro Inverter Logger Device Connect Summary Device Make Sure Phone Connected to WiFi Network Please Make Sure Phone Connected to WiFi then Click Next 15:38 Back Connect WiFi SN: 4005854756 Enter Netwo. 5. Step 1: Use your phone to scan the QR code to download and register the Solis Cloud APP. Connect your laptop to the Solis Wi-Fi network - this has a name which looks like "AP-xxxxxxxxx" 3. What do I do next? We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. 2. The consent submitted will only be used for data processing originating from this website. Solis Monitoring. How do you connect Solis? A Solis 5K inverter is used here as an example.Please follow the instructions below:Install the datalogger: NOTEOnly rotate the black circle, not the sliver cover. If you have not already been registered onSolisCloud, please see Step 18:SolisCloudMonitoring Platform. on solis S3-WIFI WiFi Stick Datalogger Installation Guide, solis GPRS Stick Datalogger Instruction Manual. Manage Settings SolisCloud is the new generation of intelligent PV system monitoring. We use cookies to try and give you a better experience in Freshdesk. 0:00 / 1:28 Reset instruction for Solis Datalogger Solis 46.7K subscribers Subscribe 130 37K views 3 years ago When the datalogger fails, you can try to reset it to repair. Solis monitoring system can be monitored remotely by WIFI and GPRS to provide users accurate and comprehensive data analysis and fault alarm at any time and place, this makes product operation more stable and reliable, and realize stable and intelligent operation and maintenance management services. Internal DC Short: In the inverter head, or the wirebox? Verify the WIFI stick is broadcasting by looking for the WIFI transmitter AP_XXXXXXXXXX in your WIFI SSID connections. Data Logger into the port and be sure to secure it by tightening the black connector. Solis WiFi Loggers Network Strength Requirements, Solis Home Professional - Generation 2 Monitoring Platform, Account Transfer to New Monitoring Platform, Adding End-User (Customer) to Plant for Monitoring Access, Selecting Inverter Drivers on AlsoEnergy PowerTrack Monitoring, Inaccurate Production Data on Monitoring Portal, Registering Installer Account on G2 Portal, Setting Up Agency Access to Plant Monitoring, Enabling SMS Notifications on SolisCloud App, How to Create an Installer Account on SolisCloud, Create Sub-Organizations, & Manage Sub-Accounts, Deteccin falla de arco y solucin de problemas, Pantalla en blanco / LCD en blanco / Sin luces. When I am logged into the data logger via wifi the status says that it is connected and when I test the connection on the server page it seems to be all good. Gua rpida de instalacin del sistema de monitoreo para Mxico y Centro Amrica. My data logger turned out to be faulty. Verify the RSSI (signal strength) is higher than 15%. The scripts will process data from the WiFi and LAN Data . Internal DC Short: In the inverter head, or the wirebox? Note: the SolisWiFilogger can only connect to 2.4 GHz networks and is unable to connect to 5 GHz networks. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:-Reorient or relocate the receiving antenna.-Increase the separation between the equipment and receiver.-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.-Consult the dealer or an experienced radio/TV technician for help. Every solar system, regardless of size and complexity benefits from monitoring and this datalogger is the gateway to the informative online platform, SolisCloud. Status indicator, easy to display working status, RESET button, one key to send data, convenient debugging, Number of connected inverters (Connect the inverters by RS485 cables. Log in to the page , the username is "admin" and the password is also "admin" 5. These limits are designed to provide reasonable protection against harmful interference in a residential installation. 2. If the WIFI stick doesn't show a connected inverter check the address of the inverter. When there is a problem with any of the Solis inverters, plant operation and maintenance (O&M) professionals will appreciate that the GinlongPro APP will connect to the inverter's data logger. *, We appreciate your effort and will try to fix the article. Solis Data Loggers. how to set up wifi stick in Solis inverter | Solis Data Logger Setup - YouTube 0:00 / 4:51 how to set up wifi stick in Solis inverter | Solis Data Logger Setup Infinite Laboratory. Solis WIFI and LAN Data Logger Datasheet.pdf, Solis WIFI Logger Installation Manual v2.4 (1).pdf. If the WIFI stick shows the inverter but you don't have data on the monitoring portal follow these steps: If it is not pingable verify the router password again. Trying to connect to 5GHZ signal (Solis DLS-W only supports 2.4 ghz signals), 4. Internal DC Short: In the inverter head, or the wirebox? Sorry we couldn't be helpful. Step 2: If it is a new data logger, please configure it first, then click the Willi configure. If you hate cookies, or are just on a diet, you can disable them altogether too. Ginlong Solis(Stock Code: 300763.SZ) is one of the oldest and largest global string inverter specialists, that manufactures string inverters for converting DC to AC power and interacting with utility grid, which help reduce the carbon footprint of human s The
What Is A 3 Level Scorer In Basketball,
How To Prepare Fly Agaric For Trip,
Articles S